MULTIPLE POWER OUTLET - 3 SOCKETS WITHOUT CABLE

CODE 11517.6 | RED-BLACK | PAC/PCS 12

MULTIPLE POWER OUTLET - 3 SOCKETS 2m

CODE 11517.1 | RED-BLACK | PAC/PCS 12

MULTIPLE POWER OUTLET - 3 SOCKETS 4m

CODE 11517.3| RED-BLACK | PAC/PCS 12

proizvod-demo.png

TMULTIPLE POWER OUTLET - 3 SOCKETS WITHOUT CABLE

CODE 11517.7 | BROWN-BEIGE | PAC/PCS 12

MULTIPLE POWER OUTLET - 3 SOCKETS 2m

CODE 11517.2 | BROWN-BEIGE | PAC/PCS 12

MULTIPLE POWER OUTLET - 3 SOCKETS 4m

CODE 11517.4 | BROWN-BEIGE | PAC/PCS 12

proizvod-demo.png

MULTIPLE POWER OUTLET - 5 SOCKETS WITHOUT CABLE

CODE 11518.6 | RED-BLACK | PAC/PCS 12

MULTIPLE POWER OUTLET - 5 SOCKETS 2m

CODE 11518.1 | RED-BLACK | PAC/PCS 12

MULTIPLE POWER OUTLET - 5 SOCKETS 4m

CODE 11518.3| RED-BLACK | PAC/PCS 12

proizvod-demo.png

MULTIPLE POWER OUTLET - 5 SOCKETS WITHOUT CABLE

CODE 11518.7 | BROWN-BEIGE | PAC/PCS 12

MULTIPLE POWER OUTLET - 5 SOCKETS 2m

CODE 11518.2 | BROWN-BEIGE | PAC/PCS 12

MULTIPLE POWER OUTLET - 5 SOCKETS 4m

CODE 11518.4 | BROWN-BEIGE | PAC/PCS 12

Technical specification “Multiple portable sockets”

MULTIPLE PORTABLE SOCKETS WITH SWITCH

  • Nominal values: 16A, 250 V ~
  • For connection of electric device up to 3500 W
  • With the folding coupling two-pole grid detachment is achived as well as the inclusion control
  • Inclusion points according to the C2a, IEC Publ.83 norm.
  • Socket ports are placed on the longitudinal axis of the socket, they enable the inflow of 'L' socket
  • Flexible connecting rod H05VVF3G 1 mm2 ili 1,5 mm2 with the socket of C2b (ili C4) IEC Publ. 83 norm.
  • The possibility of touch protection installment.

MULTIPLE PORTABLE SOCKETS

  • Norms:: HRN IEC 60884-1, DIN 49440
  • Nominal voltage: 250V
  • Rated current: 16A

OVERVOLTAGE PROTECTION AND TELECOMMUNICATION PART

  • Norms: DIN EN 61643-11
  • Test Mark : dve
  • SPD (USG) Tip 3: klasa ili spec. inf. tipa Uoc=3000V
  • Highest permanent voltage Uc: 260V~/ 50-60 Hz
  • Drainage current (8/20 μs)
  • L/PE i N/PE < 1,5 kA
  • L/N 1,5 kA
  • Protection level 1,5 kA (8/20 μs)
  • L/PE i N/PE < 1,5 kA
  • L/N <1,5 kA
  • Time to process:
  • L/PE i N/PE < 500 ns
  • L/N <25 ns

OVERVOLTAGE PROTECTION AND TELECOMMUNICATION PART

  • Norms: DIN EN 61643-21
  • Projected voltage 230V=
  • Projected power 200 mA
  • Drainage strike power (8/20 μs, 300 udara) 500 A
  • Max. Strike power (8/20 μs, 1 impuls) 5 kA
  • Protection level 500 A (8/20 μs) < 55V
  • Protection level 5 kA (8/20 μs) < 400V
  • Suppression of passing signal (300 Hz 4000 Hz) <0,1 dB